# The Cable Code

> The Cable Code is a freemium MCP server for engineering simulation. Decode cable designations across 71 coding systems and run cable design and sizing checks. It runs as a hosted remote server, so there is nothing to install locally.

- **Kind:** MCP server
- **Pricing:** Freemium
- **Starting price:** $32 a month
- **Platforms:** API, Web
- **Website:** https://thecablecode.com/developers
- **MCP Registry name:** io.github.exquad/thecablecode
- **Categories:** engineering simulation, manufacturing
- **Listing updated:** 2026-11-15

## About

The decoder is deterministic and uses no language model: give it a designation such as NYY-J 3x1,5 and it lists every coding system that can read the whole code, ranked, with each symbol, the layer it describes, its materials and the source of its meaning. Ambiguous codes return several matches rather than one guess.

Beyond decoding, the 25 tools cover designing a cable from a sentence or a spec (layers sized by IEC 60502 and IEC 60228, a DIN VDE 0276 designation, exports such as DXF, STEP and PDF datasheets), finding equivalents, rating and checking cables, and installation work such as pull calculations, tray and conduit fill, drum loading and fire class. Designs are described as a nominal calculation from standards, not a manufacturer datasheet.

No account or API key is needed. The first few calls a day are free, after which calls are paid in USDC over x402 by clients that support it. The site's separate paid plans, in dollars, sell more of the designer and datasheet reading in the web app.

## Features

- **Multi-system decoder:** Reads a designation against 71 coding systems and ranks the matches.
- **Cable designer:** Sizes layers from a sentence or a spec and writes the designation.
- **Equivalents:** Finds equivalent cables across systems.
- **Installation calculators:** Pull, tray fill, conduit fill, drum loading and burial depth.
- **Document readers:** Extract datasheet data and read tender documents.
- **Pay per call:** Free daily allowance, then USDC per call via x402.

## Good for

- Decode a cable marking found on site
- Design an MV cable and export a datasheet
- Convert an IEC cable to its NEC counterpart for a bid
- Check tray fill for a cable route
- Plan how drums load onto a truck

## Install

### Claude Code (Terminal)

```sh
claude mcp add --transport http thecablecode https://thecablecode.com/mcp
```

### Claude Desktop (Settings → Connectors → Add custom connector)

```sh
https://thecablecode.com/mcp
```

### Cursor (~/.cursor/mcp.json)

```json
{
  "mcpServers": {
    "thecablecode": {
      "url": "https://thecablecode.com/mcp"
    }
  }
}
```

### VS Code (.vscode/mcp.json)

```json
{
  "servers": {
    "thecablecode": {
      "type": "http",
      "url": "https://thecablecode.com/mcp"
    }
  }
}
```

### Windsurf (~/.codeium/windsurf/mcp_config.json)

```json
{
  "mcpServers": {
    "thecablecode": {
      "serverUrl": "https://thecablecode.com/mcp"
    }
  }
}
```

### Other clients (your client's MCP settings (most use this shape))

```json
{
  "mcpServers": {
    "thecablecode": {
      "type": "http",
      "url": "https://thecablecode.com/mcp"
    }
  }
}
```

## Tools

- `decode_cable_code`: Decode a cable type designation (DIN VDE, HAR, BS/IEC, NEC, TS, UTE, CEI-UNEL and 64 more of its 71 coding systems, plus LAN and fibre) into its layers: conductor, insulation, screen, armour, sheath, with the source behind each symbol. Deterministic, no LLM.
- `design_cable`: Design and size a cable (power, control, LAN, coaxial, fibre) from a sentence (any site language, e.g. "3-core collective screen 12/20 kV 3x95/25 Al, longitudinally watertight") or a spec: every layer's thickness with its source (IEC 60502, HD 603 / 620, BS, EN 50525, NEC / UL and more; IEC 60228), the overall diameter, the designation and the decoder's reading of it, and the estimated weight, ben
- `find_equivalents`: Find the equivalents of a power cable in other countries' standards ("the Dutch equivalent of this Swedish cable"): the decoded cable is rebuilt under each target rule set (IEC 60502, HD 603, HD 620 sections J/M/D/C/K, BS 5467/6724/7846/6622, EN 50618, HD 627) with the same conductor, section, cores, voltage, screen, armour and sheath, then compared layer by layer with the source of every value. V
- `overhead_conductor`: Look up a bare overhead line conductor (AAC, AAAC, ACSR, ACSR/AW: aluminium or alloy wires, with or without a zinc coated or aluminium-clad steel core): send its code, e.g. "242-AL1/39-ST1A" (EN 50182:2001 4.5) or an ACSS code "401-AL0/28-MEHST" (FprEN 50540 clause 4), or an EN 50182 Annex F country table ("F.19") with an optional row. Each row comes back as the standard prints it, with its table,
- `check_cable`: Check a power cable against a standard's nominal rules: a designation with size and voltage, a designer design, or the construction a maker's datasheet or tender offer states (layers with nominal and minimum thicknesses, screen and armour data). Rule sets: the 85 that the standard field lists (IEC 60502, IEC 60228, IEC 60840 / 62067, IEC 62930, HD 603, HD 620, HD 627, BS, IS, DIN VDE 0250 / 0271 /
- `extract_datasheet`: Read a power cable datasheet (a maker PDF, an https link to one, or pasted datasheet or tender text) into constructions: every cable size it states with voltage, cores, conductor, each layer with its nominal and smallest thickness, screen and armour data, diameters and the claimed standards, each with the page and the row it was read from, the values that could not be read and the ones the reader 
- `read_tender`: Read a project or tender document (a purchase or project specification, a tender volume, a GTP / data schedule; a PDF of up to 80 pages and 20 MB, or its text) and answer what it asks for: every cable it lists built as a design by the designer's rules and checked against its rule set, the required / offered schedule beside the document's own required values with their pages, each requirement mappe
- `write_specification`: Write the cable specification for a tender: one cable, or a project of up to 30 cables, each as design_cable takes it (a sentence, a bare designation, a spec or a design), plus the project's requirements (rodent, termite, UV, cold, oil, watertightness, fire, armour and more, each with the construction chosen to meet it). Returns, per cable, the specification in tender order (scope, standards, cons
- `design_presets`: List what the cable designer builds, before calling design_cable: presets[] (power, MV, HV, North American, building wire, cords, control, LAN, coaxial, fibre), each with its id, standard, the sentence that builds it in design_cable, its designation (name), voltage, cores, section and metal; and spec_standards[], every family a design_cable spec may name in spec.standard, with its voltages, core c
- `drum_fit`: Which cable drum (reel) a length of cable needs, or how much one drum takes: whole layers and whole turns wound nested (each turn in the groove of the layer below, layers rising 0.866 dc) on a wound diameter of 1.05 x OD with a freeboard under the flange rim; cable makers' own capacity tables count aligned layers and print about 11 to 18 % less, and a drum wound loosely may hold less. Drums are KT
- `burial_depth`: The minimum burial cover for a power cable by country, voltage and location (open ground, road, pavement; direct or in a raceway for the US and Australia), from the rule the site holds for that country (national rules, HD 603 / HD 620 parts, NEC 2026 Tables 300.7(A) and 305.15(A), IS 1255), with its source and seen level; null with the reason where none was read. Free, deterministic, no LLM.
- `fire_class`: The lowest fire class or listing a country asks for in a kind of building or space (escape route, general area, high-rise, tunnel, hospital, data centre, plenum, riser, railway) for DE, ES, FR, GB, IT, TR and US: the rule lines with their sources and seen levels, makers' declarations marked as such, the US NEC 2026 Article 722 listing ladders (CMP, CMR, CL3P, OFNP ...) with what may replace each b
- `awg_metric`: AWG / kcmil against IEC 60228 mm², both ways, by area and by maximum resistance at 20 °C (4/0 AWG is not 95 mm²), each size with its resistance and source (NEC Chapter 9 Table 8, UL 1581 Table 30.3, IEC 60228:2023 Table 4, 0.5 to 3500 mm²); with k, the ICEA insulation constant K (MΩ·1000 ft at 15.6 °C) in MΩ·km and why it cannot be checked against an IEC Ki. Send awg or mm2 (one of them), metal Cu
- `conduit_fill`: NEC Chapter 9 conduit fill: the smallest trade size of a raceway type (EMT, IMC, RMC, PVC, ENT, FMC, LFNC, LFMC, HDPE ...) that holds a list of conductors or cables, their areas from Tables 5, 5A and 8 (or a cable by its diameter) against Table 1's 53 / 31 / 40 % (60 % for a nipple), with the fill and the jam ratio of three conductors; each area with its table, and the rows a table lacks named. Fr
- `pull_cable`: The designer's pull calculation on a route of straights and bends (a conduit or rollers): the tension out of each segment pulled from either end, the sidewall bearing pressure at each bend, the jam ratio, clearance and fill, against the allowable tension and pressure with their sources (makers' and utilities' pulling rules), and the governing limit. Without full and without payment the answer is t
- `tray_fill`: The NEC cable tray fill (392.22, Tables 392.22(A)(1), (A)(5), (A)(6), (B)(1)) and the ampacity of each cable in the tray (392.80), for 2000 V and below and Type MV: the fill against the allowable area or width, pass or fail, and each cable's derated ampacity with its table. For a conduit or other raceway use conduit_fill (free); for one cable's IEC rating use design_cable. Without full and without
- `drum_loading`: The drum page's loading planner: how many vehicles of a type (box trailer, curtain-sider, open top, flat rack, containers, platform, rigid truck, or a custom box in full mode) a number of drums needs, by space and by payload, the rows and positions, chocks and bedding, the securing (wedges, blocking along the axis, tipping, top-over lashings per drum forwards, sideways and backwards and the LC a d
- `cold_weather_check`: The Pro cold-weather check: the long-term mean daily minimum and mean temperature of a place in a month (NASA POWER monthly data of the place's grid cell, GeoNames places, a stored table: no outside call) against the design's minimum laying temperature with its source, and a verdict: comfortable, marginal, prewarm or unknown. A place by its GeoNames id or by coordinates (its nearest place in the t
- `mv_electrical`: The Pro electrical values of a medium or high voltage design: capacitance, charging current, inductive reactance in trefoil and flat, a.c. resistance with the skin and proximity effects (IEC 60287-1-1), dielectric loss and the impulse levels (IEC 60502-2), every value with its source; what no source gives is listed as missing. Always paid: the site shows them to members only. input: {freq: 50 | 60
- `economic_size`: The Pro economic size (the IEC 60287-3-2 method): the energy lost a year in this size and one and two sizes up, its present cost over the years, and the discounted payback of the larger size where its extra cost is given, each step with its formula and source. Always paid: the site shows it to members only. input: {amps (first-year maximum load), hours (a year in service), mu (loss-load factor), p
- `commissioning_sheet`: The Pro commissioning sheet for a design: the tests after installation of its voltage (the rows of design_cable after_installation, IEC 60502-2 clause 20, IEC 60840, IEC 62067, HD 620, BS, IEEE 400.2), each with its voltage, duration and source, as a PDF with fields to record the results. A separate paid call: its own price, never inside the design price. input: {tests?: [row ids of after_installa
- `cable_prep`: Prepare the end of an LV, MV or HV power cable for its termination or joint. The answer (thecablecode.prep/v1): steps[], each cut with the design's own depth and the diameter left; the makers' cut-back lengths for this voltage and size (makers' published instructions, unnamed, seen typical; none for low voltage); lug (the lug family by conductor class and metal, its standards, the strip length rul
- `iec60287_rating`: The Enterprise IEC 60287 calculation: the continuous current rating of one circuit of three single cores of a medium or high voltage design, in trefoil or flat, buried direct, in buried ducts (one cable in each) or in free air, bonded at both ends, single-point or cross-bonded, at the site conditions sent (IEC 60287-1-1:2006+A1:2014 and IEC 60287-2-1:2015, read at standard level page by page): eve
- `degassing_time`: The Pro degassing estimate (research/degassing/PLAN.md): how many days an XLPE core stays in the oven until a share of its crosslinking by-product is left, by Fick diffusion with published coefficients (Polymers 11 (2019) 1439; the methane D0 and Ea of IEEE PES T&D 2016 as quoted there; Electric Wire & Cable 2025 at 65 C), never a standard's result: no standard gives a degassing formula, time or r
- `equivalence_report`: The Pro equivalence report (server/pro/equivalence.ts, as a member downloads it under the equivalents panel): an IEC power cable in mm² against its North American counterpart in the same role (low voltage: XHHW-2 or USE-2 / RHW-2 (UL 44) or THHN / THWN-2 (UL 83) at the smallest AWG / kcmil size whose area is at least the IEC section; medium voltage: UL 1072 MV-105, the conductor compared, the wall

## FAQ

### Do I need an account or API key?

No. Calls are free up to a daily allowance, then paid per call in USDC with x402.

### What are the free limits?

5 free decodes and 2 free designs per caller per UTC day.

### Is the decoder AI-based?

The site says it is deterministic with no LLM.

### How do I add it to Claude Code?

claude mcp add --transport http thecablecode https://thecablecode.com/mcp

### How many tools are there?

25.

### Is The Cable Code free?

The Cable Code has a free plan, with paid plans for more usage or features. Paid plans start at $32 a month.

### How do I add The Cable Code to Claude Code?

Run this command in your terminal: claude mcp add --transport http thecablecode https://thecablecode.com/mcp

### What are the best alternatives to The Cable Code?

The closest alternatives to The Cable Code are Petrolytx: decline curves and well economics, Cutlab CNC, ProofPass, 轻排生产排产（MRP-PMC） and zumen-gate.

## Alternatives

- [Petrolytx: decline curves and well economics](https://ai-powered.com/mcp/petrolytx-decline-curves-and-well-economics): Petrolytx: decline curves and well economics is a freemium MCP server for analytics and data.
- [Cutlab CNC](https://ai-powered.com/mcp/cutlab-cnc): Cutlab CNC is a paid MCP server for manufacturing.
- [ProofPass](https://ai-powered.com/mcp/proofpass): ProofPass is a freemium MCP server for legal and government.
- [轻排生产排产（MRP-PMC）](https://ai-powered.com/mcp/mrp-pmc): 轻排生产排产（MRP-PMC） is a freemium MCP server for manufacturing.
- [zumen-gate](https://ai-powered.com/mcp/zumen-gate): zumen-gate is a freemium MCP server for engineering simulation.
- [Gradient Dynamics: thermal and CFD simulation](https://ai-powered.com/mcp/gradient-dynamics-thermal-and-cfd-simulation): Gradient Dynamics: thermal and CFD simulation is an MCP server for engineering simulation.
- [naja-scope](https://ai-powered.com/mcp/naja-scope): naja-scope is an open-source MCP server for developer tools.
- [Formada3D 3D Printing](https://ai-powered.com/mcp/formada3d-3d-printing): Formada3D 3D Printing is a paid MCP server for design and media.

---
Source: https://ai-powered.com/mcp/the-cable-code
